DownloadsNewsContact    
  Home PageSoftware PageCMM RetrofitSupportContents    
 
Support ContractCurrent VersionTraining ProgramWhat'S NewDownloadsFAQFeedback
Sitemap


Introduction  |  Features  |  Enhancements  |  Bug Fixes

Axel32 Version 5.45-5.34 Release Notes

27 February 2004

Introduction

This document provides list of features, enhancements, bug fixes since version 5.34 till 5.45. See below for a complete list.

Features

Description
Pipe Import Data: Creating Pipe from imported data file

 Top



Enhancements

Date Type Description
29.01.04   Printout set/clear additional buttons for all features in printout confuration dialog.
14.01.04 Pipe Inches envelope errors outside tolerance not highighted
- Tolerance Band [PASS] / [FAIL] text added.
- Supplementary pipe data updated after units change.
- Result preview window updated after units change.
    HTML export - part name field
06.01.04   Result boxes options (All,In tolerance,Out of tolerance) working in 3D view
22.12.03 CNC - program after error always stay in pause, then it can be run or stopped
- cnc error causes to switch to joystick mode, run or step reenables cnc mode
- permament error like emergency stop and limits display message box until
the error dissapears
  Pipe Pipe nominal table import.
Pipe data dialog - Load button imports text file which contains nominal data.
Program reads only lines which contain 3 numbers (separated by comas or space)
The numbers should be x y z or y b c, depends on the current selection in dialog.
exmpl.
0.000, 0.000, 0.000
10.000, 0.000, 0.000
29.696, 3.473, 0.000
No other data is read at the moment. Nomber of strights is determined by number
of correctly read lines.
Other data like tube diameter and bend radius for a moment have to be set
manually until file format for those will be defined.
10.12.03   Result options dialog - "Save as default" checkbox option added for Results options are saved for each view separately with the part file Default values are used for all views of the New part.
    Coordinate systems ignored for zoom all in both MW and 3D views.
    Axel header in raport text box - date and time placed in the sepearate line
the same changed in save results to file.
27.11.03   Additional text info and logo in axe splash bitmap, data in axel.ini
Example for itp.
[AxelSplash]
User=ITP
EnableUserData=1
Text1=ITP
Text2=www.itpgroup.co.uk
Text3=itp@itpgroup.co.uk
;picure 122x80 pix, no stretch done
Bitmap=itplog3d_small.bmp)
    AxReport notifies Axel about report file and its disk path. Its location is
now remembered with part file (previous default search path was 'parts' dir).
Axel gets the report name in the moment of load/save/close the raport.s
22.11.03   New 22-characters code to avoid characters mistyping. (Previous version of axel still accept 20-char code)
17.11.03   3-axis joystick support. Accesible though F2 toggle (a small icon appears in the probe status). In Setup menu there is Joystick setup
12.11.03   Modifiations inside calibration program :
- measure points slightly above the equator (80 deg of the sphere)
- message about probe psitioning is diaplyed only for the first position
- corrected moves to avoid the stem
- increased margin, but later there will be access to this parameter from the dialog
Calibration sphere uses its nominal diameter for drawing in MW and 3d instead
of measured like other features do.
Selection colour is disabled in 3d for the calibration sphere.
23.10.03   Message property dialog of the feature. Del key now can be used in the editor.
The dialog box is closed before feature is deleted.
14.10.03 Surface Enabled draw of safety planes in 2d views. This is for MW view only (change of 3rd mouse coordinate - Ctr+Shift+LBmouse move)
24.09.03   PChanges in 3d save bitmap/export regarding bitmap size.
Now definition of the size is in mm/inch plus selection of dpi.
  CNC With learn option "Use standard program" switched off, now there is possibility
of selecting existing feature from the list (measured erlier), press
remeasure function (instead of new fetaure). Learn will insert Measure-Finish
comands.
    3d Points mode points can now be selected when geometry is referenced
to any system
    3D model position updated after changing geometry reference system
12.09.03   Bitmap added to standard printout, setup in printout page of
options dialog. It is a global setup for all parts
09.09.03   Fonts of standard printout header lines changed
26.08.03   Geometry transform dialog, removed change of checkboxes after coord system change view
    Increased size of expression string in cnc command
    Increased size of expression string in UserRes feature (to 255 characters)

 Top



Bug Fixes

Date Type Description
06.01.04   Error closing dialog for tolerance edit for multiple features
22.12.03   Error that might occur when cancel not finished fetaure during creating with data points source mode, in 3d view
10.12.03 Surface Fixed difference between points coordinates of the best fit in data table
and results of surface points used for the calculation.
Before proper values was those in surface points results.t
04.12.03   Error while Exit Axel after using 3D fixed
    Corrected error with moving ph10 head even when doesn't require change
28.10.03   Report now is notified about feature name change and 3d view change.
    Corrected behaviour of open file dialog in the Stage Errors dialog
    Correction of 3d view in element coordinates after read part file
    Fixed ocasional runtime error when switching to 3d view
    Play sound button in sounds setup fix
09.10.03 Surface Corrected size of SP picture in 3d. Now the size in mm is the circle diameter, the same in pixels. SP in exising parts will look 2x smaller, correction in the setup options
may be needed. SP picture setup is stored with the part file (no change there).
24.09.03   Result boxes in 3d updated after editing tolerances.
    Dongle message appears in front of splash logo
    Error with probe file name when named axel.prb
12.09.03 Pipe Corrected pipe inch results - last digit rounding
  Pipe Corrected Bend i Dia pipe results in nominals table - in inch
09.09.03   Problem with saving DXF file
26.08.03 Surface Corrections in best fit calc with mindev and maxdev optimization type
26.08.03   Geometry transform dialog, removed change of checkboxes after coord system change view