DownloadsNewsContact    
  Home PageSoftware PageCMM RetrofitSupportContents    
 
Support ContractCurrent VersionTraining ProgramWhat'S NewDownloadsFAQFeedback
Sitemap


Introduction  |  Features  |  Enhancements  |  Bug Fixes

Axel32 Version 5.77-5.75 Release Notes

6 January 2006

Introduction

This document provides list of features, enhancements, bug fixes since version 5.46 till 5.68. See below for a complete list.

Features

Description

DMIS Import: DMIS import module has been released.

 

 Top



Enhancements

Date

Type

Description

9.01.06 Pipe Pipe slot brackets
Bracket types available in the pipe wizard have been extentd with round and rectangular slots.
They can be selected globaly in the 'Parameters' page or individually in the 'Brackets' table in the tast column (its a 3-state switch working with dblclick or spacebar)
By defult results enabled for slots are centre xyz and width. Generated slot has length equal to with (its a 'dia' value)
5.12.05   Enabled possibility of moving fetaures on the list in case of pipe part.
CNC Edge point cnc program EP_PT__.SEQ modified. Added two parameters to work with 4-point EP feature.
2.11.05   Edge point Number of points added (2 or 4 can be selected)
  CNC CNC Learn - Protection against using a standard program for learn.
27.10.05 CNC CNC program during run now also is checking motm_StatusChanged message. Previously only mot_ReadAxisStatus function was used during program run.
3.10.05 DMIS DMIS slot feature
At the moment axel always creates rectangular slot (program W8BHJ07H43 has ROUND parameter, but measure points fits
rectangular slot)
DMIS DMIS probe setup in options
Setup of dmis probe direction in case there is no SNSMNT command in the program.
NOTE : Mounting axis (probe Z) direction points towards the machine arm (not the tip end)
Probe X axis is where probe is pointing whith 90,0 angles.
30.09.05 DMIS DMIS editor
SAVE menu command enabled
23.09.05   DMIS program files loaded with the part file
  Axel off-line joystick mode enabled if pc-joyctick not connected
25.08.05   Auto-add plane to the circle.
If program adds a plane, and the status working plane is not 3D, then the plane become status current working plane.

12.07.05

CNC

New CNC commands added
MoveToRel
MoveByRel
with paraneter RelFetuare, which can be plane or point.
Move destination point is modified according to the RelFeature measured deviation.

05.07.05   Part file version control
In the part open dialog there are informations about part version number.
One is the part file selected, and the current one for comparision. The same information is in Part-Properies-Statistics.

When saving a part that was created with previous file ver, there is a message box with information and question if realy save the file in new version.

Relation between Axel release verions and part file versions contain file part_files_release.txt

    Result labels - there is a choice of up to three columns :
measured, nomina, deviations to be displayed in the box.
Selection is done in the Option-Result Type checkboxes.
(At least one column is forced to be selected).
Each column has headre letter above, respectively M, N, or D

28.06.05

 

Arc_Pla1 program corrected
(ref. 27/06/05)

25.06.05

 

Added some pan modes in 3d view with shift key

Menu options\buttons LB LB+Ctrl LB+Shift LB+Ctr+Shift
----------------------------------------------------------------------------
None - ROT - PAN
Pan mode - PAN - ROT
Mouse rotation mode ROT - PAN -
Mouse rotation mode+ Pan mode PAN - ROT -

Zoom in/out with RB works whenever ROT or PAN is active.

16.06.05

 

Auto calibration - order of calibrated tips now set according to the probe tips list.

 Top



Bug Fixes

Date

Type

Description

16.01.06

 

Corection of grid display in 3D view - the grid would not always show.

3.01.06   AxRep - fixed error about printer bin

 

 

Distance feature - Dist result upper tolerance modified so it doesn't accept negative number

9.11.05 Pipe Pipe bestfit end points options
Best fit with point option Dn calculation has been corrected. Now pipe end points can have Dn-axis option checked (in best fit options table). This gives correct best fit in case the end points are shifted along the tube ends. Only distance to the tube nominal axis will be taken into calculation.

Now if there is at last 5 pipe points, axel enabled Dn end points by default during pipe generating.
At the moment this function can be disabled in axel.ini file:
[Pipe]
BfitEndPtDn=0

The Dn optin can be also changed manually in best fit option property.

30.09.05

DMIS

DMIS Probes.
This gets a bit more complicated at the moment.
I have found out that the programs are probably designed for probe
directions +Y-X-Z (in axel notation), while itp machine is -Y+X-Z.
Unfortunately the programs doesnt contain definition of the probe mount,
and all commands SNSDEF has mount axis 0,0,1 (which is equivalent of axel -Z).
As an experiment I have added to the dmis interface command SNSMNT which
defines all directions of the probe mount.
It deifnes ZVEC (our AB0 dir) and XVEC (our A90 dir).
NOTE : dmis ZVEC points towards the machine, while axel AB0 is along the probe tip (the opposite)
If you put a dmis line in at the beginning of program :
SNSMNT/XVEC,-1.0,0.0,0.0,ZVEC,0.0,-1.0,0.0,MNTLEN,0.0,0.0,0.0
it defines that the program was designed for probe +Y-X-Z.
Now the dmis angles will be translated to the -Y+X-Z (probe which is
set in axel before translation (DMISProbe)
NOTE : the command is valid inside single program, so should be added
to each one before translation.

 

DMIS

DMIS Alignment Rotation + Plane fixed

12.09.05

CNC

3D view RB mouse data points.
Taking data ponits with mouse RB was sometimes incorrect if the grid was displayed on top of the cad model.

 

 

Correted updat of nominal table bend and radius after editing default bend and radius in the first tab of the pipie data dialog. It was not always updated when changing mm-inch because of some numbers rounding.

 

Pipe

Pipe - corrected update of pipe points nominals in case of nominals coordinates start from not 0,0,0 point

15.08.05

 

PH_CAL2 program modified to work correctlty with horizontal arm (moves between position change)

14.07.05

Pipe

Pipe - generating pipe with plane intersection end point type there was
no probe diameter used correctly if the fetaures already existed befor.
generation.

16.06.05

 

Wrong value of pla_angstart of arc_pla4 when created in learn.

 

 

Correction of an error in ARC_PLA4.SEQ

10.06.05

Pipe

Generating pipe - sart and end planes has added correction points This is important for end with flange, where direction of first flange cylinder is determined by circle reference plane - the flange plane.

08.06.05

IGES

IGES import
- A message box added after end of loading about not processed iges entities
- Added iges offset curve

14.05.05

CNC

Plane feature calculation
If a plane is contructed from point fetaures, the direction will be
taken form correction of one of the points to set plane normal side.

 

CNC

CPH10 'hand control unit not connected' status was taken as an error and
prevent futher ph communication.

 Top

 
Copyright © 2005 AXEL SYSTEMS LTD. ALL RIGHTS RESERVED  |   Site Map  |  Contact Top